並列タイトル等Irradiation Performance Test of PuO2-UO2 Fuels by Saxton Reactor
一般注記Mixed oxide(PuO$_{2}$-UO$_{2}$) fuel rods (fourrods and one assembly containing 68 rods) were irradiated to certificate irradiationperformance of proto-typed fuel by SaxtonReactor to peak burnups of up to 80,500 MWD/MTM. Linear power level was from 200 to 500 watts/cm. After irradiation,post-irradiationexaminations were conducted in Battelle's Columbus Laboratories (BCL). The postirradiation examinations were consisted of visual examination, profilometry, gamma scanning, fuel and clad metallography, burnup analysis, hydride analysis in claddings and clad strength tests. These examinations showed that the overall performance of the PuO$_{2}$-UO$_{2}$ fuel was satisfactory.
None
一次資料へのリンクURL/PNC-TN841-74-49.pdf (fulltext)
連携機関・データベース国立情報学研究所 : 学術機関リポジトリデータベース(IRDB)(機関リポジトリ)
提供元機関・データベース日本原子力研究開発機構 : JOPSS:JAEA Originated Papers Searching System