並列タイトル等Three Dimensional Flow Measurement in the Axial Compressor with a Single Slanted Hot-Wire
タイトル(掲載誌)航空宇宙技術研究所報告 = Technical Report of National Aerospace Laboratory TR-603
一般注記To measure three-dimensional air flow in the axial flow compressors, several kinds of slanted hot-wire anemometery techniques have been developed in recent years. Quick response and less disturbance to the flow are the typical advantages of this method of measurement. In our experiment, the measuring system consists of a hot-wire anemometer with a single slanted wire probe and a data processing system. Exit flow of the axial flow compressor with 15 rotor blades is measured by the system. The anemometer output signals, obtained by locating a probe at three positions in each 120deg orientations, are sampled, averaged and calculated using the directional consines techinque. The resulting processing data show the values for three-dimensional components of mean velocity, swirl angle and pitch angle. The decay and the diffusion of the rotor wakes are also presented.
資料番号: NALTR0603000
レポート番号: NAL TR-603
一次資料へのリンクURLhttps://jaxa.repo.nii.ac.jp/?action=repository_action_common_download&item_id=44858&item_no=1&attribute_id=31&file_no=1
連携機関・データベース国立情報学研究所 : 学術機関リポジトリデータベース(IRDB)(機関リポジトリ)
提供元機関・データベース宇宙航空研究開発機構 : 宇宙航空研究開発機構リポジトリ