本文へ移動
博士論文

Comparison of compressive forces caused by various cannulated cancellous screws used in arthroscopic ankle arthrodesis. 12

博士論文を表すアイコン
表紙は所蔵館によって異なることがあります ヘルプページへのリンク

Comparison of compressive forces caused by various cannulated cancellous screws used in arthroscopic ankle arthrodesis.

国立国会図書館永続的識別子
info:ndljp/pid/10951943
資料種別
博士論文
著者
Kamijo, Satoshiほか
出版者
BioMed Central
授与年月日
2017-06-28
資料形態
デジタル
ページ数・大きさ等
-
授与機関名・学位
奈良県立医科大学,博士(医学)
詳細を見る

国立国会図書館での利用に関する注記

本資料は、掲載誌(URI)等のリンク先にある学位授与機関のWebサイトやCiNii Research外部サイトから、本文を自由に閲覧できる場合があります。

資料に関する注記

一般注記:

type:ThesisBackground: When performing arthroscopic ankle arthrodesis for end-stage ankle arthritis, internal fixation is performed using bone screws ...

書店で探す

障害者向け資料で読む

目次

提供元:国立国会図書館デジタルコレクションヘルプページへのリンク
  • 2024-05-04 再収集

  • 2024-05-04 再収集

  • 2024-05-04 再収集

書誌情報

この資料の詳細や典拠(同じ主題の資料を指すキーワード、著者名)等を確認できます。

デジタル

資料種別
博士論文
巻次・部編番号
12
著者・編者
Kamijo, Satoshi
Kumai, Tsukasa
Tanaka, Shogo
Mano, Tsuyoshi
Tanaka, Yasuhito
出版事項
出版年月日等
2017-01
12
出版年(W3CDTF)
2017-01
並列タイトル等
鏡視下足関節固定術で使用される中空海綿骨螺子による圧着圧の比較
タイトル(掲載誌)
Journal of Orthopaedic Surgery and Research
掲載ページ
Article No.7-
ISSN(掲載誌)
1749799X
授与機関名
奈良県立医科大学
授与年月日
2017-06-28
授与年月日(W3CDTF)
2017-06-28
報告番号
乙第1403号
学位
博士(医学)
博論授与番号
乙第1403号
本文の言語コード
eng
対象利用者
一般
一般注記
type:Thesis
Background: When performing arthroscopic ankle arthrodesis for end-stage ankle arthritis, internal fixation is performed using bone screws after appropriate preparation. However, optimal characteristics of bone screws have not been examined in terms of pressure force. Objective comparisons of bone-screw performance may provide information on procedures for arthroscopic ankle arthrodesis. The study objectives were to determine whether it was possible to measure compressive force changes using the newly developed device and to infer all screw characteristics from measurement results when used in actual surgeries. In addition, we performed experiments on cadavers to verify whether the experimental results could be applied to the joints of living subjects. Methods: Three types of screws (S1, S2, and S3) were inserted into the unique measurement device, and the changes in pressure were measured for each 45° turn. Changes in pressure and maximum pressure force were recorded after the application of the screws. After reaching the maximum pressure in the simulated bone, further screw rotations were accompanied by a gradual pressure decrease to 0 MPa. We also measured pressure changes in a similar manner by inserting a miniature pressure sensor into the talocrural joints of cadavers. Results: The mean maximum pressure ± standard deviation for S1, S2, and S3 were 0.832 ± 0.164 MPa, 0.434 ± 0.116 MPa, and 0.414 ± 0.127 MPa, respectively. Pressure slopes to the maximum did not significantly differ between the screws in the simulated bone, and a subsequent pressure decrease to 0 MPa was significantly more rapid for S1 than for S2 and S3. Although pressure failure after the overtightening of screws was only observed in the simulated bone, patterns of pressure vs. rotation angle were similar in simulated and cadaveric bones. The pressure profile characteristics of three different screw types were determined. Conclusions: We were able to measure the compressive force changes using the newly developed device when the screws were inserted. On the basis of the measurement results, we were able to infer the characteristics of all screws when used in actual surgery.
博士(医学)・乙第1403号・平成29年6月28日
Copyright © The Author(s). 2017 Open Access This article is distributed under the terms of the Creative Commons Attribution 4.0International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, andreproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link tothe Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver(http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.
identifier:Journal of Orthopaedic Surgery and Research Vol.12 Article No.7 (2017 Jan)
identifier:1749799X
identifier:http://ginmu.naramed-u.ac.jp/dspace/handle/10564/3349
identifier:Journal of Orthopaedic Surgery and Research, 12: Article No.7
国立国会図書館永続的識別子
info:ndljp/pid/10951943
コレクション(共通)
コレクション(障害者向け資料:レベル1)
コレクション(個別)
国立国会図書館デジタルコレクション > デジタル化資料 > 博士論文
収集根拠
博士論文(自動収集)
受理日(W3CDTF)
2017-09-02T15:28:24+09:00
記録形式(IMT)
application/pdf
オンライン閲覧公開範囲
国立国会図書館内限定公開
デジタル化資料送信
図書館・個人送信対象外
遠隔複写可否(NDL)
連携機関・データベース
国立国会図書館 : 国立国会図書館デジタルコレクション