並列タイトル等中国東部及び中部における種々の建築パラメータが伝統的住居のエネルギー消費に及ぼす影響に関する研究
一般注記The research results indicate that (1) Optimum building azimuth: the three building azimuth intervals with the highest energy saving potentials were observed for S, S-E20 and S-E40 in sequence. (2) Optimum shading depths recommended for each building azimuth interval: the recommended shading depths for S and S-E 20 are 1.37 m and 1.62 m respectively, and those for S-E 40, S-E 60, S-E 80, S-W 20 and S-W 40 are all 2.12 m, as well as those for the other 11 BAs are all 2.37 m. (3) Optimum window-to-wall ratios recommended for each building azimuth interval: the recommended window-to-wall ratios for 18 building azimuth intervals are all 0.2. (4) Optimum wall construction type recommended for each building azimuth interval: the recommended wall construction type for 18 building azimuth intervals are all the vented cavity wall with increased outer layer thickness.