Jump to main content
可塑化ポリ塩化ビニル...

可塑化ポリ塩化ビニル膜型電極検出器を用いる陽イオン界面活性剤のフローインジェクション分析

Icons representing 記事

可塑化ポリ塩化ビニル膜型電極検出器を用いる陽イオン界面活性剤のフローインジェクション分析

Call No. (NDL)
Z17-9
Bibliographic ID of National Diet Library
3706524
Material type
記事
Author
正留 隆ほか
Publisher
東京 : 日本分析化学会
Publication date
1991-01
Material Format
Digital
Journal name
分析化学 / 日本分析化学会 編 40(1) 1991.01
Publication Page
p.p1~6
View Details

Detailed bibliographic record

Summary, etc.:

A flow system for the determination of cationic surfactants in the presence of anionic surfactant is proposed. The system consists of a micro-column p...

Holdings of Libraries in Japan

This page shows libraries in Japan other than the National Diet Library that hold the material.

Please contact your local library for information on how to use materials or whether it is possible to request materials from the holding libraries.

other

  • J-STAGE

    Digital
  • CiNii Research

    Search Service
    Digital
    You can check the holdings of institutions and databases with which CiNii Research is linked at the site of CiNii Research.

Bibliographic Record

You can check the details of this material, its authority (keywords that refer to materials on the same subject, author's name, etc.), etc.

Digital

Material Type
記事
Author/Editor
正留 隆
今任 稔彦
石橋 信彦
Periodical title
分析化学 / 日本分析化学会 編
No. or year of volume/issue
40(1) 1991.01
Volume
40
Issue
1
Pages
p1~6
Publication date of volume/issue (W3CDTF)
1991-01
ISSN (Periodical Title)
0525-1931
ISSN-L (Periodical Title)
0525-1931
Publication (Periodical Title)
東京 : 日本分析化学会
Place of Publication (Country Code)
JP
Text Language Code
jpn
NDLC
Target Audience
一般
Article Type
記事分類: 化学・化学工業--油・脂--界面活性剤
Collection (particular)
国立国会図書館デジタルコレクション > 電子書籍・電子雑誌 > 学術機関 > 学協会
Access Restrictions
インターネット公開
Availability of remote photoduplication service
不可
Holding library
国立国会図書館
Call No.
Z17-9
Related Material (Persistent ID (NDL))
info:ndljp/pid/10892546
Data Provider (Database)
国立国会図書館 : 国立国会図書館雑誌記事索引
Bibliographic ID (NDL)
3706524
Bibliographic Record Category (NDL)
632

Digital

Summary, etc.
A flow system for the determination of cationic surfactants in the presence of anionic surfactant is proposed. The system consists of a micro-column packed with anionexchange resin and a surfactant-selective polyvinyl chloride membrane electrode detector. The membrane was plasticized with phthalic acid di(2-ethylhexyl) ester. Anionic surfactants were removed by the anion-exchange resin column. The cationic surfactant was eluted by methanol/H<SUB>2</SUB>O=50/50(v/v, %) and detected. The electrode detector showed the linear response with a potential slope of 45 mV/decade for dodecyltrimethylammonium (DTA) ion from 5×10<SUP>-7</SUP> to 1×10<SUP>-5</SUP> M. The detection limit for DTA was 1.0×10<SUP>-8</SUP>M. The proposed method was free from interferences from coexisting inorganic electrolytes, anionic surfactants and nonionic surfactants. By this method, a trace level of cationic surfactants in river water could be determined.
微量の陽イオン性界面活性剤を陰イオン性界面活性剤及び非イオン性界面活性剤の存在下で分析するためのFIAシステムを開発した.このシステムは陰イオン性界面活性剤を除去するための陰イオン交換樹脂カラムとフタル酸ジ(2-エチルヘキシル)で可塑化したポリ塩化ビニル膜を感応膜とする界面活性剤電極から成る.陰イオン性界面活性剤は陰イオン交換樹脂に吸着させ,陽イオン性界面活性剤のみをメタノール/水=50/50(v/v,%)で溶出し,界面活性剤電極で検出する.電極は5×10<SUP>-7</SUP>Mから1.0×10<SUP>-5</SUP>Mの濃度範囲のドデシルトリメチルアンモニウム(DTA)イオンに対して45mV/decadeの直線的電位応答を示す.検出下限濃度は約1.0×10<SUP>-8</SUP>Mであった.この方法は,5×10<SUP>-7</SUP>MDTAの定量に対して塩化ナトリウムのような無機電解質が1万倍,陰イオン性界面活性剤,非イオン性界面活性剤が100倍過剰に共存しても妨害を受けない.本法により河川水中の微量陽イオン性界面活性剤の定量が可能であった.
DOI
10.2116/bunsekikagaku.40.1
Access Restrictions
インターネット公開
Data Provider (Database)
科学技術振興機構 : J-STAGE

Digital

Summary, etc.
微量の陽イオン性界面活性剤を陰イオン性界面活性剤及び非イオン性界面活性剤の存在下で分析するためのFIAシステムを開発した.このシステムは陰イオン性界面活性剤を除去するための陰イオン交換樹脂カラムとフタル酸ジ(2-エチルヘキシル)で可塑化したポリ塩化ビニル膜を感応膜とする界面活性剤電極から成る.陰イオン性界面活性剤は陰イオン交換樹脂に吸着させ,陽イオン性界面活性剤のみをメタノール/水=50/50(v/v,%)で溶出し,界面活性剤電極で検出する.電極は5×10<SUP>-7</SUP>Mから1.0×10<SUP>-5</SUP>Mの濃度範囲のドデシルトリメチルアンモニウム(DTA)イオンに対して45mV/decadeの直線的電位応答を示す.検出下限濃度は約1.0×10<SUP>-8</SUP>Mであった.この方法は,5×10<SUP>-7</SUP>MDTAの定量に対して塩化ナトリウムのような無機電解質が1万倍,陰イオン性界面活性剤,非イオン性界面活性剤が100倍過剰に共存しても妨害を受けない.本法により河川水中の微量陽イオン性界面活性剤の定量が可能であった.
Access Restrictions
インターネット公開
Is Referenced By
A New Microfluidic Polymer Chip with an Embedded Cationic Surfactant Ion-selective Optode as a Detector for the Determination of Cationic Surfactants
化学センサーの開発と流れ系分析への応用
Data Provider (Database)
国立情報学研究所 : CiNii Research
Original Data Provider (Database)
Japan Link Center
雑誌記事索引データベース
雑誌記事索引データベース
Crossref
国立国会図書館デジタルコレクション
CiNii Articles
Crossref
Crossref
NAID
110002906182