Search by Bookstore
Holdings of Libraries in Japan
This page shows libraries in Japan other than the National Diet Library that hold the material.
Please contact your local library for information on how to use materials or whether it is possible to request materials from the holding libraries.
other
JOPSS:JAEA Originated Papers Searching System
DigitalYou can check the holdings of institutions and databases with which Institutional Repositories DataBase(IRDB)(Institutional Repository) is linked at the site of Institutional Repositories DataBase(IRDB)(Institutional Repository).
Search by Bookstore
Bibliographic Record
You can check the details of this material, its authority (keywords that refer to materials on the same subject, author's name, etc.), etc.
- Material Type
- 規格・テクニカルリポート類
- Author/Editor
- 岩下 強古田 恵岡崎 光芳碓井 幸博宮本 久也
- Publication Date
- 1996-01
- Publication Date (W3CDTF)
- 1996
- Alternative Title
- Study of improvement of simulation performance for JOYO simulator
- Periodical title
- PNC TJ9164 96-001
- Target Audience
- 一般
- Note (General)
- 出版タイプ: NAFBR大型炉の安全性向上に不可欠な各種の炉内試験を可能とするために高速炉安全試験炉(略称:SERAPH)が計画されている。SERAPH炉の具体的な炉心概念構築のために,軽水炉取出Puを使用した5\%Pu02-Be0ドライバー燃料から構成されるナトリウム冷却型炉心と重水型炉心において,制御棒形状やフォロワー材質について制御系に関わる広範囲なサーベイを行った。その結果つぎの結果が得られた。・Na冷却-2スロット型炉心では,チャンネル型制御棒・Naフォロアーとの組合せを持つ炉内配置案で炉停止能力の見通しが得られた。入熱係数は約2.2となった。・重水冷却型炉では制御棒に関して,重水排除フォロワーと組合せにより,チャンネル型,クラスター型・Y字型制御棒システムでは,設定した配置案において所定の炉停止能力の確保の見通しが得られた。入熱係数は1.4$\sim$1.7となった。一方,使用するPu同位体組成比は過剰反応度・制御棒システム設定に大きな影響を持つので,炉心性能向上検討と併せて組成比設定検討が重要である。また,連続エネルギーモンテカルロ法を使用して,入熱係数,出力分布について,実効拡散係数を使用する拡散計算手法との比較を行い,計算精度評価を行った。JOYO simulator(FOSTER) has been operated for operational training and also evaluation of specific operation such as low coolant flow test. This study was carried out for arrangement of remodeling items for MK-III and for improvement of simulation performance. At first, in order to improve preciseness of simulation of normal operation and abnormal operation by FOSTER, we evaluated simulation results of FOSTER and FBR plant dynamic analysis code MIMIR-N2, selecting typical eight event. We confirmed that Foster has satisfactory simulation excepting behavior of natural circulation condition and low coolant low condition. Also, in order to improve simulation accuracy of control rod reactivity and response of NIS indication, we investigated details for improvement of soft-ware and hardware, and arranged remodeling items for MK-III. For strengthen supervisory function of plant condition, we designed monitoring display for non-measured parameter and emergency condition.
- Source
- /PNC-TJ9164-96-001.pdf (fulltext)