Search by Bookstore
Holdings of Libraries in Japan
This page shows libraries in Japan other than the National Diet Library that hold the material.
Please contact your local library for information on how to use materials or whether it is possible to request materials from the holding libraries.
other
JOPSS:JAEA Originated Papers Searching System
DigitalYou can check the holdings of institutions and databases with which Institutional Repositories DataBase(IRDB)(Institutional Repository) is linked at the site of Institutional Repositories DataBase(IRDB)(Institutional Repository).
Search by Bookstore
Bibliographic Record
You can check the details of this material, its authority (keywords that refer to materials on the same subject, author's name, etc.), etc.
- Material Type
- 規格・テクニカルリポート類
- Author/Editor
- 坂本 淳志木部 智川野邊 一則藤咲 和彦佐野 雄一竹内 正行鈴木 英哉津幡 靖宏伴 康俊松村 達郎
- Publication Date
- 2021-06
- Publication Date (W3CDTF)
- 2021
- Alternative Title
- Evaluation of the mass transfer coefficients for the minor actinide separation; Evaluation by the single drop method
- Periodical title
- JAEA-Research 2021-003
- Target Audience
- 一般
- Note (General)
- 出版タイプ: NA日本原子力研究開発機構(JAEA)では、使用済核燃料溶解液中からマイナーアクチノイド(以下、「MA」という)を回収するプロセスの一つとして、SELECTプロセスの適用が検討されている。SELECTプロセスでは従来から用いられてきたリン(P)系の抽出剤ではなく、炭素(C),水素(H),酸素(O),窒素(N)といった非リン系のみで構成される新たな抽出剤を開発し、その適用検討を進めているところである。その中でMA・ランタノイド(以下、「Ln」という)を一括回収するための抽出剤として$N,N,N',N'$-tetradodecyldiglycolamide(テトラドデシルジグリコールアミド(以下、「TDdDGA」という))、MA/Lnを相互分離するための抽出剤として$N,N,N',N',N",N"$-hexaoctylnitrilotriacetamide(ヘキサオクチルNTAアミド(以下、「HONTA」という))、Am/Cmを相互分離するための抽出剤としてAlkyl diamide amine(アルキルジアミドアミン(ADAAM))を用いたフローシートの構築を進めている。本試験では、SELECTプロセスにおいてラフィネート中からMA及びLnを回収するためのTDdDGA及びHONTAを対象に、フローシートを構築する上で必要となる物質移動係数の取得を単一液滴法により進めた。単一液滴法により物質移動係数を評価するに当たっては、あらかじめ装置の形状変更等の改良を重ねた上で試験的な評価を実施し、既報値と同様な物質移動係数値が得られることを確認した。また、取得したTDdDGAの物質移動係数を用いることで、これまでにmixer-settlers(ミキサセトラ(MS))やcentrifugal contactors(遠心抽出器(CC))を用いて実施してきた連続多段試験結果の妥当性についても評価することがdできた。さらに、HONTAに関しても評価を行い、10$^{-6}$m/s以下の低い物質移動係数を有することが明らかとなった。Japan Atomic Energy Agency has been developing a solvent extraction process called SELECT to recover minor actinides (MA) from spent nuclear fuel. In the SELECT process, TDdDGA, HONTA, and ADAAM are used as the extractants for MA + Ln corecovery, MA/Ln separation and Am/Cm separation, respectively. These extractants do not contain phosphorus (P), and consist of carbon (C), hydrogen (H), oxygen (O), and nitrogen (N). In this study, in order to give beneficial information for designing flowsheet, the mass transfer coefficients of Ln between HNO$_{3}$ solution and TDdDGA or HONTA / n-dodecane solvent were evaluated by the single drop technique. Prior to the evaluation of mass transfer coefficient, we had optimized the structure of the single drop apparatus to improve accuracy of the measurement. Based on the mass transfer coefficients obtained in HNO$_{3}$ / TDdDGA-n-dodecane system, Ln behaviors in the counter-current extraction and back-extraction using mixer-settlers and centrifugal contactors were estimated by simple calculation, and they had a good agreement with our previous experimental results. We also confirmed the mass transfer coefficients of Ln in HNO$_{3}$ / HONTA - n-dodecane system are under 10$^{-6}$ m/s.
- Source
- /JAEA-Research-2021-003.pdf (fulltext)