Alternative Title乳房ソナゾイド造影超音波における背景乳腺の造影効果についての検討
Periodical titleJournal of medical ultrasonics
Note (General)type:Thesis
Purpose: The objective of this study was to retrospectively evaluate the association between background parenchymal enhancement (BPE) on contrast-enhanced ultrasound (CEUS) with Sonazoid® and patient characteristics. Additionally, background parenchymal tissues with the high-contrast effect were pathologically observed compared to those showing the low-contrast effect. Methods: A total of 65 patients who underwent breast CEUS with Sonazoid® between January 2010 and November 2013 were enrolled. Regions of interest (ROIs) were put on the tumor and on the background parenchymal tissue. The dB values during the nonenhanced time and at peak contrast enhancement were measured based on the time intensity curve (TIC) drawn by the ROI. The differences in the dB values of pre- and post-enhanced time were obtained separately for ROIs on the tumor and ROIs on the parenchymal tissue. The patient characteristics studied were age, menstrual status, mammographic density, BPE on magnetic resonance imaging (MRI), and pathological diagnoses of breast tumors. Results: There was a weak negative correlation between BPE on CEUS and age. As for the contrast effect of parenchymal tissue, there was a significant difference between the menstruating and menopausal groups. There was no significant difference among the levels of mammographic density, and among the degrees of contrast effect on MRI. BPE on CEUS was the same between those with a malignant tumor and those with a benign tumor in each menstrual status. The parenchymal tissue with the low-contrast effect showed pathological atrophy. Conclusion: The degree of BPE on CEUS appeared related to age, menstruating or menopausal, and atrophy of breast tissue. BPE on CEUS was the same between those with a malignant tumor and those with a benign tumor in each menstrual status.
博士(医学)・乙第1508号・令和3年3月15日
© Springer Nature Singapore Pte Ltd. 2020.
© The Japan Society of Ultrasonics in Medicine 2020.
This is a post-peer-review, pre-copyedit version of an article published in Journal of medical ultrasonics. The final authenticated version is available online at: https://doi.org/10.1007/s10396-020-01052-4.
identifier:Journal of medical ultrasonics Vol.47 No.4 p.591-601 (2020 Oct)
identifier:13464523
identifier:http://ginmu.naramed-u.ac.jp/dspace/handle/10564/3934
identifier:Journal of medical ultrasonics, 47(4): 591-601
DOIinfo:doi/10.1007/s10396-020-01052-4
Collection (particular)国立国会図書館デジタルコレクション > デジタル化資料 > 博士論文
Date Accepted (W3CDTF)2022-03-06T04:54:00+09:00
Data Provider (Database)国立国会図書館 : 国立国会図書館デジタルコレクション