新規骨固定補助装置は顎整形治療を想定した即時高荷重条件下でも歯科矯正用アンカースクリューの安定性を向上させる
Available in National Diet Library
Find on the publisher's website
NDL Digital Collections
Digital data available(The E. H. Angle Education and Research Foundation)
Search by Bookstore
Read this material in an accessible format.
Table of Contents
Provided by:国立国会図書館デジタルコレクションLink to Help Page
2024-01-19 再収集
2024-01-19 再収集
2024-01-19 再収集
2024-01-19 再収集
Search by Bookstore
Read in Disability Resources
- Other Services
Bibliographic Record
You can check the details of this material, its authority (keywords that refer to materials on the same subject, author's name, etc.), etc.
- Material Type
- 博士論文
- Author/Editor
- 山形, 勁太
- Author Heading
- Publication, Distribution, etc.
- Publication Date
- 2022-10-18
- Publication Date (W3CDTF)
- 2022-10-18
- Alternative Title
- A novel auxiliary device enhances the miniscrew stability under immediate heavy loading simulating orthopedic treatment
- Degree Grantor
- 鹿児島大学
- Date Granted
- 2022-10-18
- Date Granted (W3CDTF)
- 2022-10-18
- Dissertation Number
- 甲総研第672号
- Degree Type
- 博士(歯学)
- Text Language Code
- eng
- Subject Heading
- Target Audience
- 一般
- Note (General)
- 出版タイプ: VoR博士論文全文, 博士論文要旨, 最終試験結果の要旨, 論文審査の要旨Objectives: To evaluate miniscrew stability and perform a histomorphometric analysis of the bone around the miniscrew under a load corresponding to orthopedic force.Materials and Methods: Thirty-two miniscrews were implanted into eight rabbit tibias. Auxiliary group rabbits received auxiliary devices with miniscrews (n = 8, 28 days; n = 8, 56 days), and those in the nonauxiliary control group received miniscrews without auxiliary devices (n = 8, 28 days; n = 8, 56 days). Elastics were placed between miniscrews to apply a load of 5 N. Miniscrew stability was evaluated using a Periotest. Bone-to-implant contact (BIC) and spike implantation depth were measured histomorphologically.Results: Periotest values in the auxiliary group were significantly lower than those in the nonauxiliary group at all time periods. There was no significant difference in BIC between the auxiliary and nonauxiliary groups at 28 or 56 days postimplantation. The implantation spike depth in the auxiliary group was significantly greater at 56 days compared to that at 28 days. Newly formed bone was observed around the spike of the auxiliary device at 56 days.Conclusions: The results suggest that the use of miniscrews in conjunction with auxiliary devices provides stable skeletal anchorage, which may be useful in orthopedic treatments.Keita Yamagata, Yasuhiko Oga, Sangho Kwon, Aya Maeda-Iino, Takanori Ishikawa, Shouichi MiyawakiA novel auxiliary device enhances the miniscrew stability under immediate heavy loading simulating orthopedic treatmentAngle Orthodontist (2022)https://doi.org/10.2319/022222-163.1
- Persistent ID (NDL)
- info:ndljp/pid/12509573
- Collection
- Collection (Materials For Handicapped People:1)
- Collection (particular)
- 国立国会図書館デジタルコレクション > デジタル化資料 > 博士論文
- Acquisition Basis
- 博士論文(自動収集)
- Format (IMT)
- application/pdf
- Access Restrictions
- 国立国会図書館内限定公開
- Service for the Digitized Contents Transmission Service
- 図書館・個人送信対象外
- Availability of remote photoduplication service
- 可
- Periodical Title (URI)
- Data Provider (Database)
- 国立国会図書館 : 国立国会図書館デジタルコレクション