Jump to main content
電子書籍・電子雑誌日本放射線看護学会誌
Volume number12 (2)
ピンホールカメラによ...

ピンホールカメラによる単純X線撮影・CT検査・IVR時の散乱X線発生源の可視化

Icons representing 記事
The cover of this title could differ from library to library. Link to Help Page

ピンホールカメラによる単純X線撮影・CT検査・IVR時の散乱X線発生源の可視化

Persistent ID (NDL)
info:ndljp/pid/14616930
Material type
記事
Author
小山内暢ほか
Publisher
日本放射線看護学会
Publication date
2024
Material Format
Digital
Journal name
日本放射線看護学会誌 12(2)
Publication Page
-
View Details

Notes on use at the National Diet Library

本資料は、掲載誌(URI)等のリンク先にある電子書籍・電子雑誌の提供元Webサイトなどから、本文を自由に閲覧できる場合があります。

Detailed bibliographic record

Summary, etc.:

<p>With the reduction of the equivalent dose limit to the lens of the eye, effective management of occupational radiation exposure is imperative. This...

Holdings of Libraries in Japan

This page shows libraries in Japan other than the National Diet Library that hold the material.

Please contact your local library for information on how to use materials or whether it is possible to request materials from the holding libraries.

other

  • J-STAGE

    Digital
  • CiNii Research

    Search Service
    Digital
    You can check the holdings of institutions and databases with which CiNii Research is linked at the site of CiNii Research.

Bibliographic Record

You can check the details of this material, its authority (keywords that refer to materials on the same subject, author's name, etc.), etc.

Digital

Material Type
記事
Author/Editor
小山内暢
田村梨菜
田中智妃蕗
三上葉月
野呂朝夢祐
工藤幸清
細川翔太
對馬惠
山口一郎
細田正洋
齋藤陽子
Publication, Distribution, etc.
Publication Date
2024
Publication Date (W3CDTF)
2024
Alternative Title
Visualization of scattered X-rays sources using a pinhole camera in general radiography, computed tomography examinations, and interventional radiology
Periodical title
日本放射線看護学会誌
No. or year of volume/issue
12(2)
Volume
12(2)
ISSN (Periodical Title)
2433-5649
ISSN-L (Periodical Title)
2187-6460
Text Language Code
jpn
Persistent ID (NDL)
info:ndljp/pid/14616930
Collection (Materials For Handicapped People:1)
Collection (particular)
国立国会図書館デジタルコレクション > 電子書籍・電子雑誌 > その他
Acquisition Basis
オンライン資料収集制度
Date Accepted (W3CDTF)
2026-01-16T13:17:36+09:00
Date Captured (W3CDTF)
2025-01-20
Format (IMT)
application/pdf
Access Restrictions
インターネット公開
Availability of remote photoduplication service
不可
Periodical Title (Persistent ID (NDL))
info:ndljp/pid/14616927
Data Provider (Database)
国立国会図書館 : 国立国会図書館デジタルコレクション

Digital

Summary, etc.
<p>With the reduction of the equivalent dose limit to the lens of the eye, effective management of occupational radiation exposure is imperative. This study, as one of the approaches to radiation visualization based on actual measurements, conducted a phantom study using a self-made lead pinhole camera to identify the source of scattered X-rays in general radiography, computed tomography (CT) examinations, and interventional radiology procedures. The aim is to obtain materials to optimize protection against scattered X-rays. In addition to patient phantoms, considerable X-rays were found to emanate from equipment components such as the diaphragm cover of the X-ray tube, bed, and mylar ring (the window of the gantry aperture) of the CT equipment. Recommendations include implementing more appropriate protective measures, such as improving the standing position of medical staff and adjusting how protective shield is used. Future research will quantify the pinhole image and develop the real-time visualization of pinhole images.</p>
<p>眼の水晶体の等価線量限度が引き下げられた現在、職業被ばく管理の適正化が求められている。本研究では、実測に基づく放射線可視化のアプローチのひとつとして、単純X線撮影、コンピュータ断層撮影(computed tomography: CT)検査、画像下治療(interventional radiology: IVR)を対象とし、自作の鉛製ピンホールカメラによるファントム実験にて散乱X線の発生源を特定し、散乱X線に対する防護の最適化に資する知見を収集することを目的とした。患者ファントムに加え、X線管の可動絞りカバーや寝台、CT装置のマイラリング(ガントリ開口部の窓)といった装置の構成パーツからも無視できない散乱X線が発生していることが明らかとなった。医療スタッフの立ち位置や防護板の使用方法の改善といった、より適切な防護策の検討が望まれる。今後はピンホール画像の定量化やリアルタイム化に向けて取り組みたい。</p>
DOI
10.24680/rnsj.24-002
Access Restrictions
インターネット公開
Data Provider (Database)
科学技術振興機構 : J-STAGE

Digital

Summary, etc.
<p>眼の水晶体の等価線量限度が引き下げられた現在、職業被ばく管理の適正化が求められている。本研究では、実測に基づく放射線可視化のアプローチのひとつとして、単純X線撮影、コンピュータ断層撮影(computed tomography: CT)検査、画像下治療(interventional radiology: IVR)を対象とし、自作の鉛製ピンホールカメラによるファントム実験にて散乱X線の発生源を特定し、散乱X線に対する防護の最適化に資する知見を収集することを目的とした。患者ファントムに加え、X線管の可動絞りカバーや寝台、CT装置のマイラリング(ガントリ開口部の窓)といった装置の構成パーツからも無視できない散乱X線が発生していることが明らかとなった。医療スタッフの立ち位置や防護板の使用方法の改善といった、より適切な防護策の検討が望まれる。今後はピンホール画像の定量化やリアルタイム化に向けて取り組みたい。</p>
Data Provider (Database)
国立情報学研究所 : CiNii Research
Original Data Provider (Database)
Japan Link Center
雑誌記事索引データベース
科学研究費助成事業データベース
科学研究費助成事業データベース
Bibliographic ID (NDL)
14616930